TM 11-5865-215-13
(b) Press RCL key and observe that it lights.
(c) Using DATA A/DATA B key and keyboard numerics enter de-
sired sequence of stored receiver commands according to
register selections. For example, if registers A9, B9,
A8, B8, and A2 are to be preset in sequence, entries must
be made in order shown in table 3-2. As many as 31 com-
binations of the 20 programmed receiver commands may be
preset in this manner.
(d) To verify preset sequence, press RCL key, then press and
release the AUTO STEP key repeatedly to manually step
through the sequence. Observe that correct register key
is lit during each step.
NOTE
To erase the entire preset sequence, press RCL key,
then the CLR key twice.
(2) Auto-step sequence mode activation.
--.
Observe that AUTO STEP and HOLD
(a) Press AUTO STEP key.
keys light.
(b) Press START key. Observe that START key lights and the
HOLD key goes out. In addition, the register file number
and associated receiver command is displayed on the key-
board according to the preset stepping sequence.
NOTE
If an AUTO STEP sequence has not been previously set,
the START and HOLD keys will flash. This flashing
is stopped by pressing the CLR key.
Sequence Presetting Example
Resulting
Press
step sequence
Press
Press
DATA A/DATA B
Press
STO
1st step = Register A9
A
9
RCL
STO
9
2nd step = Register B9
B
RCL
STO
3rd step = Register A8
8
A
RCL
STO
4th step = Register B8
8
B
RCL
2
STO
5th step = Register A2
A
RCL
3-9
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |