Page Title: Auto-Sweep (Tuning) Control Mode
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 11-5865-215-13
(c) Adjust SWEEP/STEP RATE control for desired stepping rate.
(d) Auto-step operation is stopped by pressing HOLD key.
(START key goes out and HOLD key lights).
(e) Auto-step mode is deactivated by pressing lit AUTO STEP
key.  Observe that AUTO STEP key light goes out.
e.  Auto-Sweep (Tuning) Control Mode.  This mode allows the opera-
tor to select a range of frequencies which the receiver automatic-
ally sweeps.
(1) Auto-sweep limit presetting.
Press AUTO SWEEP key.
Observe that AUTO SWEEP and HOLD
(a)
keys light.
Select desired upper frequency limit using keyboard nu-
(b)
meric(s).   O b s s r v e  selected  frequency  on  TUNING  FREQUENCY
(MHz) display.
Press STO key and observe that it lights.
(c)
Press F2 and observe that it lights.
(d)
Select desired lower frequency limit using keyboard nu-
(e)
merics.  Observe selected frequency on TUNING FREQUENCY
(MHZ) display.
Press STO key and observe that it lights.
(f)
Press F1 key and observe that it lights.  Note that if,
(g)
after START-key is pressed, the F1 and F2 keys flash on
and off, one of the following conditions exists:
The sweep range is too small for the selected receiver
1.
2.
The upper frequency limit (F2) is less than the lower
limit (F1).  Flashing is deactivated by pressing the
CLR key.
(h) To examine stored frequency limits, press RCL key and
the desired limit key (F1 or F2).
(2) Auto-sweep/manual tuning activation.
(a) After performing steps in paragraph 3-4e(1) above, press
START key.  Observe that START key lights and HOLD key
goes out.  TUNING FREQUENCY (MHZ) display is now changing
at a rate controlled by SWEEP/STEP RATE control.  Press
HOLD key to stop frequency sweep operation.  Observe that
START key goes out and HOLD key lights.  Observe also that
3-10