Lamp Replacement.
When a lamp replacement iS required, follow the instructions de-
scribed in the note below.
NOTE
If a lamp is replaced in a Jay El switch, series part
number 1063OEL, care should be taken not to distort
the lamp holder gripping fingers.  The fingers should
be adjusted using gentle pressure without the use of
pliers or tools that could distort the finger align-
ment.  Two fingers should be set "in" to grip the
lamp, and the opposite two fingers should be set "out"
to grip the switch socket.  A bottom view of the lamp
holder is shown in figure 6-9.
EL-3R4J063
Bottom View of Lamp Holder
Figure 6-9.