CHAPTER 4
DEPOT OVERHAUL STANDARDS
Section I. GENERAL
4-2. Technical Publications
4-1. Purpose of Final Testing
This manual together with TM 11-5820-549-12-1 covers
The tests outlined in this section are designed to
the equipment to be tested.
measure  the  performance  capability  of  repaired
equipment. Equipment that is to be returned to stock
should meet the standards given in these tests.
4-3. Test Facilities Required
The following equipments, or suitable equivalents will be
employed  in  determining  compliance  with  the
requirements of this Specific Standard.
Quantity
a. Test Equipment
Federal stock no.
required
Technical Manual
6625-445-6933
1
TM 11-6625-617-12
Nomenclature
6625-911-6368
1
TM 11-6625-700-10
6625-669-0228
1
TM 11-6625-355-12
Power Supply PP-3514/U
6625-643-1670
1
TM 11-6625-320-12
Digital Readout Electronic Counter AN/USM-207
6625-181-1884
1
TM 11-6625-937-12
Oscillator, Audio TS421A/U
6625-360-2493
1
TM 11-6625-200-15
Voltmeter, Electronic ME-30A/U
6625-242-5023
1
TM 11-6625-366-15
Indicator, Channel Alignment ID-1189(XE-2)/PR
6625-244-0501
1
TM 11-5017
Multimeter ME-26/U
6625-720-8352
1
TM 11-1275
Multimeter TS-352B/U
6625-868-8353
1
TM 11-6625-573-15
Output Meter TS-585A/U
6625-668-9418
1
TM 11-5097
Signal Generator AN/URM-103
Signal Generator AN/GRM-60
Analyzer, Spectrum TS-723A/U
4-4. Test Harnesses
b. Materials
Quantity
The equipment can be tested with conventional rf,
Material
Federal stock no.
audio, and dc test cables. Use a subminiature phone
Required
plug for connection to headset jack.
Capacitor, 5.0 pf 0.5 pf
1
Capacitor, 2.2 pf 10%
1
4-5. Organization of Tests
Resistor, 39 ohms 1%,
1
1/2 w.
Tests for Receiving Set, Radio AN/PRR-9(XE9) are
Resistor, 50 ohms 1%,
1
given in section II of this chapter.  The tests are
1/2 w.
organized in the most logical manner for rapid testing,
Resistor, 75 ohms 5%,
1
and to utilize the same or similar test setups for
1/2 w.
successive tests. Whenever a change in frequency is
required, the AN/PRR9 (XE-9) or AN/PRT-4 should first
c. Rf Pad.  An rf pad for testing the AN/ PRR-
be alined on the ID-1189(XE-2)/PR.
9(XE-9) is required and is illustrated in figure 4-1.
Materials for the rf pad are included in b. above.
4-1