NAVSHIPS 0967-217-4010
TM 11-5895-490-20
of  the  AUDIO-LIGHT  switch  on  the
2-6. Stopping Procedure
C-6280 (P) /APX as foIlows:
Set the controls on the C-6280 (P) /APX as
follows:
(1) Place the AUDIO-LIGHT switch in
AUDIO. Mode 4 interrogating and
reply pulses will be audible in the
Position
Control
pilot's headset and visible on the RE-
OFF
MASTER control
PLY light.
OUT
IDENT-MIC switch
(2) Place the AUDIO-LIGHT switch in
OUT
M1, M2, M-3/A, M-C, and
LIGHT. Indication of mode 4 inter-
MODE 4 switches
rogating and reply pulses will be vis-
OUT
AUDIO-LIGHT switch
sible on the REPLY light.