Click here to make tpub.com your Home Page

Page Title: Table 5-1. Troubleshooting Procedures - continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-6350-264-14&P-12
NAVELEX EE 181-AA-OMI-120/E121 C-7359-60-1
TO 31S9-2FSS9-1-12
Table 5-1. Troubleshooting Procedures - Continued
Corrective action
Probable cause
Trouble
volts/division
e. (cont)
@2v
2. (cont)
time/division
@10ms
input
@dc
Connect scope probe to A2-TP6,
blue. Connect scope ground to
A4-TP3, orange. The scope
should display clock signal as a
squarewave of 6.8 0.4 vdc, and
81.3 to 85.4 ms (11.7 to 12.3
Hz). Maintain this check for a
period of time to ensure that
clock is stable.
b. If clock signal is good, use oscilloscope
to check FSK signal on Data Re-
ceiver PC board A4. Set oscillo-
scope as follows:
volts/division
@2v
time/division
@0.1ms
input
@ac
At the Receiver connect scope
probe to A4-TP6, blue. Connect
scope ground to A4-TP3, orange.
At the transmitter, ground A1-TP5
(green) by connecting a jumper
from A1-TP5 to transmitter chas-
sis. The scope should display FSK
signal as a sine wave of 9 0.5 vac,
and 0.81 to 0.76 ms (1231.9 to
1308.1 Hz). Maintain this check
for a period of time to ensure that
FSK signal is stable.