Quantcast Table 5-1. Troubleshooting Procedures - continued - TM-5-6350-264-14-P-120031

 

Click here to make tpub.com your Home Page

Page Title: Table 5-1. Troubleshooting Procedures - continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
Table 5-1. Troubleshooting Procedures - continued - TM-5-6350-264-14-P-120030
Up
TM-5-6350-264-14-P-12 Receiver Data R-1861/FSS-9(V) NSN
Next
Table 5-1. Troubleshooting Procedures - continued - TM-5-6350-264-14-P-120032
TM 5-6350-264-14&P-12
NAVELEX EE 181-AA-OMI-120/E121 C-7359-60-1
TO 31S9-2FSS9-1-12
Table 5-1. Troubleshooting Procedures - Continued
Corrective action
Probable cause
Trouble
from A1-TP5 to Transmitter chas-
f. (cont)
1. (cont)
sis. The scope should display FSK
signal as a squarewave of 6 1 vdc,
and 0.81 to 0.76 ms (1231.9 to
1308.1 Hz).
Do NOT short A1-E14 to chassis/
ground or equipment will be
damaged.
f. Disconnect jumper from A1-TP5 and
chassis. Connect jumper to A1-E14 and
A1-TP5. The scope should display
FSK signal as a squarewave of
6 1 vdc, and 0.96 to 0.91 ms
(1037.9 to 1102.1 Hz).
g. If either of these FSK signals is in-
correct, replace Data Transmitter.
(1) To remove Data Transmitter, tag,
identify, and disconnect wires
from TB6 and TB7. Remove
screws that secure Data Trans-
mittter to standoffs in CU. Be
careful not to drop Transmitter
inside CU. Remove screws that
secure cover and remove cover.
Remove code plug from its soc-
ket on PC board A2.
5-14